In order to evaluate the efficiency and functionality of thermal energy plants, measurements of specific operation parameters of an existing plant need to be carried out (performance testing, operatability tests, permanent operation tests, fouling test/proof together with the collection of basic data to plan and dimension the plant).
The Consultant Engineer's Office for Energy and Environmental Technology looks back on long-year experience with thermal plant and laboratory measurement technology.
We offer the following equipment / the following measurements (further equipment can be supplied by cooperation partners):
- Temperature/ temperature difference
Measurements of thermocouple elements Temperature sensors for resistance measurement NTC/PTC temperature measurement technique Radiation / infrared measurement technique
- High precision reference thermometer with 0,02K measurement inaccuracy - NIST/ITS-90-Calibration-Certificate according to ANSI/NCSL
- Heating/cooling bath with a temperature range between -40 and 200°C for the processing and conditioning of calibration, exhaust and process gases
- Pressure / pressure difference
Flow rate Mobile ultrasonic clamp-on flow meter can be installed without disrupting or influencing plant operation. Tube dimensions: DN15 to 400 Temperature range: -40 to 170°C Flow velocity: 0 to 20 m/s
- Heat / thermal capacity
Combination of flow rate and temperature measurement techniques as well as characterization of media
- Non-destructive testing of wall thickness for surfaces of heating exchange devices and appparatus (corrosion checks, abrasion inspections etc.)
Gasemissionen Various levels of measurement gas / process gas conditioning:
- dust separation
- desiccation
- washing
- dilution
- Measurement technique with online tool for
- Calibration
Calibration of our measurement equipment is realized on the premises as well as by business partners.
- Data logging
Datalogger (battery packed) with activation, control and readout via modem as well as with automatic SMS/Email failure message for
- 4 galvanically isolated inlets (U, I, RTD, TC, I/O, f)
- 8 galvanically isolated inlets (U, I, RTD, TC, I/O, f)
- 20 galvanically isolated inlets (U, I, RTD, TC, I/O, f)
- 40 galvanically isolated inlets (U, I, RTD, TC, I/O, f)
- Plant monitoring / process control
 Individual composition of data logger/measurement equipment configurations for defined measurement/ monitoring/surveillance tasks
- Critical values
In case of violation of boundary values the measurement euqipment and data loggers provided can operate auxiliary relays and/or SMS/Email messages can be transmitted.
- Online access
Online access on measurement technique via network or modem allows for funtion controls, readouts of actual and historical data and drawing of balances.
|